A Member of Parsman Group

Request a Quote
Parsman Chemical

What are you looking for?

Results will open on the website search page.

For example:
Concrete Plasticizers

FLUENTIS MM-330 Concrete Plasticizer with High Slump Retention

MM-330 Concrete Plasticizer with High Slump Retention

FLUENTIS® MM-330 concrete plasticizer is a specialized polycarboxylate ether (PCE) admixture from Parsman Chemical. It reduces mixing water and improves the workability of fresh concrete. Its formulation is suitable for mild and relatively warm temperatures. It also helps maintain the slump of ready-mix concrete during transport and before placement.

Reduced Water Demand and Increased Concrete Strength

MM-330 concrete plasticizer improves the dispersion of cement particles, enabling the production of flowable concrete with less water. A properly controlled reduction in the water-to-cement ratio can increase compressive strength and reduce concrete permeability. This admixture is used in pumpable concrete, self-compacting concrete (SCC), and high-strength concrete. Maintaining workability also facilitates concrete placement.

Benefits and Applications of MM-330 Concrete Plasticizer

  • Reduces water demand and improves the flowability of fresh concrete
  • Provides high slump retention in mild and relatively warm weather
  • Suitable for ready-mix concrete plants
  • Enhances pumpability and concrete workability
  • Helps reduce permeability and improve structural durability

Technical Properties and Performance of MM-330 Plasticizer

MM-330 concrete plasticizer is a liquid, chloride-free admixture. Parsman Chemical lists ASTM C494 Type F and EN 934-2 in its technical data sheet. The product can also be used in concrete mixes containing silica fume. Before use, engineers should assess its compatibility with the cement and other mix constituents. Preliminary trials help control slump and achieve the desired performance.

Technical Note: Engineers should determine the dosage of MM-330 concrete plasticizer based on the target slump, cement type, concrete temperature, and transport time. Concrete mix trials help establish the appropriate dosage.

Product Technical DatasheetMM-330 · PDF

Parsman Chemical Concrete Plasticizers: Selection, Dosage and Performance Control

Compare concrete plasticizers FLUENTIS® MS-350, MM-330 and MW-310; select a grade for concrete temperature, transport time and workability retention

FLUENTIS Concrete Plasticizers: PCE-Based Water Reduction and Workability Retention

Concrete plasticizers FLUENTIS® MS-350, MM-330 and MW-310 from Parsman Chemical are based on polycarboxylate ether. These three grades reduce water demand at equal workability or increase flow at a fixed water-to-cement ratio, helping control fresh-concrete behaviour and improve hardened-concrete quality. Their main differences concern temperature suitability and slump retention.

Technical benefits shared by all three grades

  • Lower mixing-water demand at equal workability: Supports higher compressive strength and lower permeability with appropriate mix design, compaction and curing.
  • Greater workability at the same water-to-cement ratio: Facilitates flowing and self-compacting concrete with a suitable mix design.
  • Optimized cement consumption: Enables simultaneous water and cement reduction in suitable redesigned mixes while maintaining strength and durability requirements.
  • Supporting durability management: Helps reduce ingress of water and aggressive agents and manage shrinkage and heat of hydration in optimized mixes.
  • Seasonal grade selection: Different grades for cold, moderate, hot and very hot conditions, rather than one formulation for every project.
Distinguish increased flow at constant water content from water reduction at constant flow. Confirm dosage and final performance using the actual project materials.

Concrete Plasticizer Applications: Grade Selection for Actual Placing Conditions

All three datasheets list self-compacting concrete SCC, high-strength, pumpable, high-durability and high-performance concrete HPC and low-permeability concrete. For MS-350 and MM-330, mass concrete is also listed.

MS-350: summer and very hot conditions

This grade is intended for summer concrete production and offers very high slump retention in very hot conditions. Maintaining workability in hot weather is central to its selection for ready-mix concrete and projects with considerable transport distances.

MM-330: transitional seasons and moderate to hot weather

This grade is intended for transitional seasons and moderate to hot conditions, with high slump retention. For plant-produced concrete requiring flow retention during delivery, verify performance against the transport and discharge schedule.

MW-310: cold and moderate weather

This grade is designed for cold and moderate conditions, with suitable slump retention in these conditions. Its datasheet also highlights strength development in cold weather; confirm dosage and setting behaviour under actual project conditions.

An admixture does not replace mix design. Assess the relevant acceptance criteria separately for self-compacting, high-strength and other special concretes.

Technical Comparison of MS-350, MM-330 and MW-310

The following table compares the specifications declared in the three datasheets. Density or pH differences alone do not indicate water-reducing capacity or final concrete strength.

PropertyMS-350MM-330MW-310
Base materialPolycarboxylate ether (PCE)
Appearance and colourDark brown liquid
Density g/cm³1.06 ± 0.021.06 ± 0.021.05 ± 0.02
pH4–63–54–6
Freezing pointApproximately 0 °C
ChlorideChloride-free
Alkali contentLess than 1%
Stated temperature conditionsVery hot; summerModerate and hot; transitional seasonsCold and moderate
Slump retentionVery highHighSuitable for cold and moderate weather
Typical dosage; % by cement mass0.3–1.5%0.20–1.5%0.2–1.5%

Technical Specifications versus Test Results

Slump-retention descriptions are qualitative datasheet statements and do not establish an identical duration for all three grades. Numerical water reduction, slump-retention time and compressive strength require a valid test report for the specific grade and mix design.

Standards Listed in FLUENTIS Plasticizer Datasheets

ProductASTM referenceShared references
MS-350ASTM C494 Type F & GEN 934-2
Iranian National Standard 2930-2; Tables 3-1 and 3-2
MM-330ASTM C494 Type F
MW-310ASTM C494 Type F

The datasheets also refer to concrete design for consistency classes, exposure conditions and durability according to EN 206. When submitting documentation to project supervision, review the grade-specific datasheet together with the test report and mix design.

Do not assume identical standard types for every grade: the datasheet for MS-350 lists Types F & G, while the other two grades list Type F.

FLUENTIS Concrete Plasticizer Dosage: Based on Cement Mass

The following ranges are declared for typical applications. Percentages refer to cement mass. Final dosage depends on cement type, materials, concrete temperature, target workability and required slump-retention time.

ModelPercentage of cement massQuantity for 350 kg of cement
MS-3500.3–1.5%1.05–5.25 kg
MM-3300.20–1.5%0.70–5.25 kg
MW-3100.2–1.5%0.70–5.25 kg

The last column calculates the declared percentage range for an assumed cement quantity; it is not a separate dosage recommendation.

Admixture dosage calculation

Admixture mass equals cement mass multiplied by dosage percentage, divided by 100. To convert kilograms to litres, divide mass by product density; the density of MW-310 differs from the other two grades.

Evaluate the selected dosage in trial mixes, then calibrate dosing equipment to the actual units used.

Use and Storage of MS-350, MM-330 and MW-310

Material preparation and addition to the mixer

All three datasheets advise against using dry aggregates without preparation. If aggregates are dry, premix them with part of the mixing water before the main mixing stage. Include this water and aggregate moisture in mix-design calculations.

Add the admixture with the water in the batching-plant mixer. When adding it to a truck mixer, provide at least 5 minutes of uniform mixing as specified in the datasheets.

Complementary admixtures for the application conditions

  • The datasheets for MS-350 and MM-330 identify the retarder Parsman Chemical R200 for additional setting delay in very hot weather and on exceptionally long transport routes.
  • The datasheet for MW-310 identifies the accelerator Parsman Chemical AX100 for faster setting and strength development in very cold weather.
  • Reactive microsilica, expansive, air-entraining and shrinkage-reducing admixtures are also listed as compatible materials. This does not authorize direct blending of concentrated products; confirm the addition sequence and combined dosage.

Quality control before site use

Check initial workability, slump loss over the transport period, mixture stability and, where required, setting time and strength using actual project materials. Repeat evaluation after changes in cement, grading, temperature or admixture combination.

Storage, packaging and safety

The datasheets state storage for at least one year in a dry place, in sealed original packaging, at 5–35 °C. Listed packaging includes 20-litre containers, 220-litre drums, and supply in 1,000-litre tanks or bulk tankers. Read the safety data sheet and packaging instructions before use.

Buying Parsman Chemical Concrete Plasticizers and Requesting a Quote

To choose between MS-350, MM-330 and MW-310, first establish temperature conditions and transport time, then determine the dosage needed for target workability through trial mixes. Price per kilogram alone is not an adequate economic comparison; cost per cubic metre depends on the confirmed dosage.

Information needed for technical advice and a quotation

  • Required model, cement type and cement content per cubic metre
  • Initial slump and required workability-retention period
  • Concrete temperature, season, transport time and placing method
  • Microsilica or other concurrently used admixtures
  • Order quantity, packaging and delivery location
MS-350: summer and very hot weather; MM-330: transitional seasons and moderate to hot weather; MW-310: cold and moderate conditions.

Request a quote and technical advice +98 21 75918

Why Choose Parsman Chemical Concrete Plasticizers?

Quality concrete starts with an admixture suited to the materials and placement conditions of your project. FLUENTIS® MS-350, FLUENTIS® MM-330 and FLUENTIS® MW-310 concrete plasticizers from Parsman Chemical are based on polycarboxylate ether. By reducing mixing water and improving fresh concrete workability, they help produce concrete with the required strength and durability. MS-350 is designed for very hot conditions with very high slump retention; MM-330 is intended for moderate and hot conditions with high slump retention; and MW-310 is intended for cold and moderate conditions. The appropriate grade and dosage are selected by assessing cement type, concrete temperature, transport time and trial mix results. For product selection, technical advice and a quotation, contact Parsman Chemical specialists.